Use 20 gauge steel studs for exterior non loadbearing curtain.
Usg defelction criteria for metal sud framing tile wall.
The key consideration is whether the assembly is for a load.
Screw lengths must be not less than 3 8 in.
Our wall framing system are comprised of zincalume zinc and aluminium coating that comes with thickness ranging from 0 5mm and above.
Chapter 2 framing.
Shear stress of the stud.
Ceiling framing must be capable of supporting the total ceiling dead load including insulation ceramic tile bonding materials and tile backer board with deflection not exceeding l 360.
Framing practices and procedures for wood and steel framing.
Shafts are enclosed early in construction and the walls are finished later along with interior partitions.
Floor framing must be covered with min 19 mm 3 4 exterior grade plywood subfloor firmly attached to assure stability.
Stud selection selection of a stud gauge and size must take into account a num ber of factors.
Recent research has shown tile to fail under some conditions when the floor is more rigid than l 360.
Bending stress of the steel stud.
Find the right steel studs limiting heights and spans and fire rated assemblies for your shaft walls.
On center systems these floors often have deflection between the joists exceeding l 360.
Also beads trims framing insulation fasteners adhesives joint compounds coatings tapes plaster finishes and textures.
We use cookies to provide a personalized site experience.
Includes details for resilient channel installation chase walls furred ceilings and walls and door and window openings.
Web crippling of stud at supports.
Our wall frames provide a durable practical and lightweight structure for internal plasterboard walls and for specific external wall systems.
Allowable deflection of the stud.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
Installation is quick and easy using components and application procedures familiar to drywall contractors.
Cgc shaft wall systems are non load bearing gypsum wall partition assemblies constructed from outside the shaft at each floor.
Spaced not more than 12 in.
If framing is 16 in.
Axial load on the stud.
The preferred limit for veneer assemblies is l 360 and should not exceed l 240.
Estimate materials and find usg equivalents for your building projects.
9 5 mm greater than the total thickness of the gypsum board being fastened.
L d deflection limit 240 l 3 m or 3000 mm 3000 d 240 d 12 5 mm.
On all studs when framing is 24 in.
For example while joist manufacturers regularly meet the standard l 360 criteria for code construction with 24 o c.